← Misinformation tracker
Partially FalseYouTube · Science

Air Dryers and 60 Bacterial Colonies: The Claim Is Real but the Number Is Misleading

In a study, researchers found as many as 60 bacterial colonies on petri dishes placed beneath restroom air dryers after 30 seconds of exposure

The argument in brief

A real peer-reviewed study did find up to 60 bacterial colonies on petri dishes placed under restroom air dryers for 30 seconds — but 60 was the maximum observed across all dryers tested, not the average. According to Nicholson et al. (2019) in Applied and Environmental Microbiology, the average for standard dryers was roughly 18–60 CFUs as a range, and dryers equipped with HEPA filters averaged just 2.4 CFUs, a detail almost universally dropped from media coverage.

The numbersAverage bacterial colonies (CFUs) on petri dishes after 30-sec exposure — Nicholson et al. 2019

Data: Applied and Environmental Microbiology, Nicholson et al. 2019

Why it spread

The number 60 is viscerally specific — it conjures an image of a petri dish crawling with life — and it landed perfectly into an existing culture-war skirmish between paper-towel loyalists and air-dryer defenders. Hygiene anxiety content spreads reliably on its own, and this story had the added fuel of a real university study to cite, giving sharers the confidence of apparent authority without requiring them to read past the headline figure.

The claim states that researchers found 'as many as 60 bacterial colonies' on petri dishes placed beneath restroom air dryers after 30 seconds of exposure. The verdict is partially false — not because the number is invented, but because the phrase 'as many as' does real work that most people sharing this claim quietly discard, turning a ceiling figure into an implied typical result.

The study is genuine and the finding is real. Nicholson et al. (2019), published in Applied and Environmental Microbiology and conducted at the University of Connecticut, exposed standard tryptic soy agar plates directly beneath dryer nozzles for exactly 30 seconds. The range of colony-forming units (CFUs) collected across standard, non-HEPA dryers ran from 18 to 60 CFUs per plate. The 60-CFU figure represents the highest single observation recorded — the worst dryer on the worst day — not what you should expect from a typical hand-dryer encounter.

The steelman version of the claim is straightforward: air dryers do measurably increase bacterial deposition compared to ambient air, and the study confirms this. Control plates left open in the same restrooms for two full minutes without any dryer airflow collected fewer than 1 CFU on average, according to the same study. That contrast is striking and legitimate. The dryer airflow is genuinely doing something, and the concern is not fabricated.

But here is precisely where the claim breaks. Nicholson et al. (2019) also tested dryers fitted with HEPA filters, and those averaged just 2.4 CFUs — barely above the ambient baseline and 25 times lower than the maximum figure being circulated. That single data point demolishes the implication that 60 colonies is an inherent feature of hand dryers rather than a feature of unfiltered models. Lead researcher Peter Setlow confirmed in a University of Connecticut Health Center press release that while detected bacteria included potential pathogens such as Staphylococcus, the majority were common environmental organisms, not a parade of dangerous germs. The Guardian and other outlets reported the '60 colonies' figure in April 2018 but stripped it of the range, the average, and the HEPA comparison entirely.

What spread was a maximum dressed up as a norm. The manipulation pattern here is selective precision: cite a real number from a real study, omit the denominator (it's the top of a range, not the center), and drop the mitigating condition (HEPA filters) that would defuse the alarm. The result is a claim that is technically defensible word-for-word — 'as many as 60' is accurate — but functionally misleading in every context it actually appears.

The tell for next time: when a health claim leads with a dramatic maximum from a study, ask immediately for the average and the control condition. If those numbers aren't in the same sentence, someone is doing the work of omission for you.

Sources

  • Applied and Environmental Microbiology (Nicholson et al., 2019)

    The 2019 University of Connecticut study published in Applied and Environmental Microbiology found that petri dishes exposed to jet air dryer airflow for 30 seconds collected an average of 18–60 colony-forming units (CFUs), with the highest counts reaching approximately 60 CFUs under some dryers. Dishes held under hand dryers with HEPA filters averaged 2.4 CFUs.

  • Applied and Environmental Microbiology (Nicholson et al., 2019) — control condition

    Control plates left open in the restroom for 2 minutes without dryer airflow collected on average fewer than 1 CFU, confirming that the elevated counts were attributable to the dryer airflow, not ambient air deposition alone.

  • University of Connecticut Health Center press release, 2018

    The lead researcher Peter Setlow confirmed that the study was conducted across multiple restrooms on the UConn campus and that the bacteria detected included potential pathogens such as Staphylococcus, though most were environmental organisms.

  • Applied and Environmental Microbiology (Nicholson et al., 2019) — methodology detail

    The study used standard tryptic soy agar plates exposed for exactly 30 seconds directly beneath the dryer nozzle. The range reported across all dryers was 18–60 CFUs per plate, meaning 60 was the upper bound, not the average or typical finding.

  • The Guardian / secondary reporting citing Nicholson et al., 2019

    Media coverage in April 2018 widely reported the '60 colonies' figure, but the primary study shows this was the maximum observed, not a consistent or average result. The average across all non-HEPA dryers was substantially lower.